SEACO INDUSTRIAL SYNTH is a range of Polyalkylene Glycol (PAG) based synthetic lubricants developed for the lubrication of calenders, bevel, spiral bevel, helical, enclosed spur and worm gear units.
INDUSTRIAL SYNTH RANGE provides the following benefits:
·Thermally stable operation at temperatures in excess of 200°C
·A product free of chlorine, sulphur and lead based materials
·Homogeneous from below the pour point to temperatures in excess of 250°C
·An anticipated service lifetime in excess of 10,000 hours at 100°C in industrial enclosed gear units
MATERIALS COMPATIBILITY
Seal types of NBR (nitrile rubber), fluoro-silicone or vinyl-methyl polysiloxane (Q) are recommended, especially in high temperature applications.
SEACO INDUSTRIAL SYNTH RANGE should not be used with polyurethane-based elastomers, leather, cork, asbestos, paper or board.
Ordinary paints will soften in the presence of LUBEMAXX INDUSTRIAL SYNTH RANGE and, as such, internal surfaces of gear units should not be painted. If painted, then a two-pack epoxy-type product should be used.
FLUSHING PROCEDURE
SEACO INDUSTRIAL SYNTH RANGE is not miscible with mineral oil or other glycol-based lubricants. When changing from other products, the unit should be run to warm the existing fluid, then drained and cleaned of any sludge. Flush with a minimum volume of the appropriate GB UNIGEAR®INDUSTRIAL SYNTH RANGE under no load until the fluid is warm, then drain and repeat if necessary. Fill the gear unit and inspect after one or two days to ensure that the lubricant is free from contaminants.
TYPICAL PHYSICAL DATA | ||||||||||||
Test | Units | METHOD | TYPICAL PHYSICAL CHARACTERISTICS | |||||||||
ISO | 150 | 220 | 320 | 460 | ||||||||
Appearance | Pale Yellow Fluid | |||||||||||
Density at 15°C | kg/m³ | IP160 | 1000 | 1001 | 1002 | 1005 | ||||||
Kinematic Viscosity @ 40°C | cSt | IP71 | 137 | 221 | 329 | 433 | ||||||
Kinematic Viscosity @ 100°C | cSt | IP71 | 22.7 | 31.8 | 44.8 | 63.7 | ||||||
Viscosity Index | IP226 | 195 | 177 | 196 | 220 | |||||||
Flash Point (Open) | °C | IP34 | 191 | 231 | 225 | 225 | ||||||
Pour Point | °C | IP15 | -30 | -30 | -30 | -30 |